Emergency and Exit Light Testing on the Sunshine Coast
Six-monthly inspection and discharge testing to AS/NZS 2293.2, with logbook records, repairs and LED upgrades for commercial, strata and industrial buildings.
Get a Free Quote
Tell us about the job and we will be in touch.
Prefer to talk? Call 0427 468 568
Make Sure the Lights Stay on When It Matters
When the power fails during a fire or emergency, emergency lights and exit signs guide people out safely. They only work if their batteries, lamps and chargers are in good order – and the only way to know is to test them.
FCS Electrical and Solar carries out emergency and exit light testing for offices, shops, warehouses, industrial sites and strata buildings across the Sunshine Coast. We test, record, repair and upgrade, so your building stays compliant and your records are ready when someone asks.
- Six-monthly inspection and discharge testing
- Logbook kept up to date
- Failed fittings and batteries repaired
- LED exit sign upgrades
- StandardAS/NZS 2293.2 inspection and maintenance
- FrequencyEvery six months
- Discharge testRated duration – normally 90 minutes
- RecordsLogbook kept on site
What We Check
Visual Condition
Fittings intact, exit signs legible and pointing the right way.
Battery Performance
Each fitting runs for its full rated duration on battery.
Lamps & Indicators
Lamps working and charge indicators showing correctly.
Faults Recorded
Any failure logged and tagged for repair.
What AS/NZS 2293 Requires
Two Parts
AS/NZS 2293.1 covers design and installation; 2293.2 covers inspection and maintenance.
Six-Monthly Testing
Every fitting is inspected and discharge tested at six-monthly intervals.
Rated Duration
Each fitting must run on battery for its rated duration – normally 90 minutes.
Discharge Tests, Function Tests and Logbooks
A function test is a short check that a fitting switches to battery. A discharge test runs every fitting on battery for its full rated duration to prove the battery can actually last. Both matter, and after a discharge test the batteries need time to recharge – so testing is best scheduled when the building is not relying on emergency lighting.
Every result goes in the logbook kept on site. That record supports your building’s fire safety maintenance records and is available for auditors and insurers.
- WhenDate of each inspection and test
- WhatEach fitting and its result
- DefectsFaults found and repairs made
Repairs, Battery Replacement and LED Upgrades
Failed batteries, lamps and chargers are the most common faults. We repair or replace failed fittings promptly and retest them, because a failed light could leave an exit path dark during an outage or fire.
Older fluorescent exit signs can be upgraded to LED, which use less power and are typically more reliable. For fit-outs and new areas, we install new emergency lighting to AS/NZS 2293.1.
- Battery replacement
- Fitting repairs and replacement
- LED exit sign upgrades
- New installations for fit-outs
LED exit upgradeHow Six-Monthly Testing Works
Book
Tell us about the building and number of fittings.
Test
Inspection and discharge testing, circuit by circuit.
Report & Logbook
Results recorded and faults reported.
Repair
A quote for any defects, then retest.
Emergency Light Testing Across the Sunshine Coast
We test emergency and exit lighting in offices, retail and hospitality premises, warehouses, industrial sites and strata common areas across the Sunshine Coast.
Emergency Light Testing FAQs
How often do emergency and exit lights need to be tested?
Under AS/NZS 2293.2, emergency and exit lighting must be inspected and tested every six months. The routine includes a discharge test where each fitting runs on its battery for at least its rated duration, normally 90 minutes. Results must be recorded in a logbook kept on site.
What is a 90-minute discharge test?
Mains power to the emergency lighting circuit is switched off so every fitting runs on its own battery. Each light and exit sign must stay lit for its full rated duration, typically 90 minutes. Any fitting that dims or fails is recorded as a defect so the battery, lamp or fitting can be replaced.
Who is responsible for emergency lighting compliance?
In Queensland the building owner or occupier is responsible for maintaining prescribed fire safety installations, including emergency lighting, and for keeping maintenance records. In strata buildings this usually falls to the body corporate for common areas. Tenants may hold responsibility under their lease, so check your agreement.
What happens if an emergency light fails its test?
The failed fitting is recorded in the logbook and reported to you with the likely cause, such as a worn-out battery, failed lamp or faulty charger. It should be repaired or replaced promptly and retested, because a failed light could leave an exit path dark during a power outage or fire.
Do exit signs need testing as well as emergency lights?
Yes. Exit signs are part of the emergency evacuation lighting system covered by AS/NZS 2293. They are inspected for visibility and correct pointing direction and discharge tested on the same six-monthly schedule as emergency luminaires, with results recorded in the same logbook.
Can my building stay open during testing?
Usually yes. Testing is carried out circuit by circuit, and normal lighting generally stays on. After a discharge test the batteries need time to recharge, so it is sensible to schedule testing when the building is not relying on emergency lighting, such as during daylight trading hours.
Other Services You Might Need
Book Emergency Light Testing
Electrical, lighting, compliance or solar – send us the details and we will come back to you with clear advice and a written quote.
- Call0427 468 568
- Emailjosh@futurecs.com.au
- Based inBuderim, Sunshine Coast QLD
- LicensedElectrical Contractors Licence 91222
Call Us on 0427 468 568
Or use the free quote form at the top of this page and we will be in touch.